The operations below are the tips to recover the errors that occurred in the abstract commands in the shortest possible time.
Obtained slit image, but stopped at some point in the midst of taking object exposures.
Case 1: AG is not moving, but telescope is pointing at the target.
1a: Execute AG.
COMMON/VGW/DoAG
Case 2: AG setup is finished.
1:b Proceed
2: Retract the slit.
3: FOCAS/IMAG/GETIMAGE
4: Enter the file names of the slit images taken at the beginning of the procedure in the memory of C1 and C2.
Exec OBS memory Instrument_name=FOCASC1=FCSA000XXXXX C2=FCSA000XXXXX
File extension name *.fits is unnecessary.
5: Enter the name of the files taken in 3 in the memory of C5 and C6.
Exec OBS memory Instrument_name=FOCASC5=FCSA000XXXXX C6=FCSA000XXXXX
File extension name *.fits is unnecessary.
6: Continue setupfield in FINE mode.
FOCAS/SPEC/SETUPFIELD MODE=FINE
Obtained mask image, but stopped at some point while taking an object exposure.
Case 1: AG is not moving, but telescope is pointing the target.
1a: Execute AG.
COMMON/VGW/DoAG
Case 2: AG setup is finished.
1:b Proceed.
2: Retract the mask.
3: FOCAS/IMAG/GETIMAGE
4: Enter the file name of the mask image (taken at the first step of the procedure) in the memory of C1 and C2.
Exec OBS memory Instrument_name=FOCASC1=FCSA000XXXXX C2=FCSA000XXXXX
File extension name *.fits is unnecessary.
5: Enter the file of the image taken in 3 in the memory of C5 and C6.
Exec OBS memory Instrument_name=FOCASC5=FCSA000XXXXX C6=FCSA000XXXXX
File extension name *.fits is unnecessary.
6: Continue SPEC/setupfield in FINE mode.
FOCAS/SPEC/SETUPFIELD MODE=FINE
1: Stop guiding.
2: Search for a guide star and re-start guiding.
COMMON/VGW/DoAG
3: Task is complete if using image mode. If inserting slit or MOS, do the followings.
3a: FOCAS/IMAG/GETIMAGE to get an image.
3b: Set the image file name taken previously with the memory command. Then re-start the setupfield with mode=fine.
1: Select a "good" star from the guide star list on Skycat. The selected star will be marked on skycat when you double-click on the list.
2: Note RA and DEC of the selected star.
3: Start reading AG with "Exec TSC AG Readout=ON, or ask the operator to take an AG image and send it to OBS. The live movie of the AG image shows up on VGW.
4: Execute the following commands from SOSS.
Exec TSC AGSH_PROBE ra=???? dec=???? f_select=cs_opt
Set RA and DEC the coordinates of the measured star. Press Exec (Interrupt) button.
5: A star appears on AG screen (the upper screen on VGW). If not, re-select another star.
6: Select a box on skycat (the lower screen on VGW) by "manual select." Select the range within the appropriate coordinates on AG_SELECT screen since the star only appears on the upper AG screen.
7: Ask the operator to stop the AG movie.
9: Press "set" button as normally on ManualSelect.
Want to start observation at the same position after intermitting due to a bad weather and etc.